Skip to main content

GMS

Deprecated

This DTO is deprecated. Please use CIMEX DTOs as reference instead.

GMS DTOs were historically used by:

Table of Contents

GMS

FieldTypeLabelDescription
equipmentvector <Equipment>
breakervector <Breaker>
energySourcevector <Energy Source>
energyConsumervector <Energy Consumer>
generatingUnitvector <Generating Unit>
intersectionsvector <Intersections>
lineSegmentvector <Line Segment>
linearShuntCompensatorvector <Linear Shunt Compensator>
loadBreakSwitchvector <Load Break Switch>
powerElectronicsConnectionvector <Power Electronics Connection>
powerTransformervector <Power Transformer>
recloservector <Recloser>
voltageRegulatorvector <Voltage Regulator>
controllableLoadvector <Controllable Load>

Top

Breaker - extends GenericSwitch

FieldTypeLabelDescription
breakingCapacityint

Top

Connected Equipment

FieldTypeLabelDescription
mridint
typeJS_ENUMJSEquipTypeunknown, breaker, disconnector, energyConsumer, energySource, fuse, generatingUnit, intersections, jumper, linearShuntCompensator, lineSegment, loadBreakSwitch, powerElectronicsConnection, powerTransformer, recloser, transformerTank, voltageRegulator, transformer, controllableLoad, last
EquipmentRefenumEquipment

Top

Controllable Load

FieldTypeLabelDescription
wattsint
varsint
isUncontrollablebool
normalOpenbool

Top

Disconnector - extends Equipment

FieldTypeLabelDescription

Top

Energy Consumer - extends Equipment

FieldTypeLabelDescription

Top

Energy Source - extends Equipment

FieldTypeLabelDescription

Top

Phase Map

FieldTypeLabelDescription
mridstring
phasestring

Top

Equipment

FieldTypeLabelDescription
rootIdstring
mridvector<string>
namevector<string>
phasestring
feederHeadbool
voltRangevector<float>
phaseMappingvector <Phase Map>
connectedEquipmentvector <topology::Connected Equipment>
locationvector <topology::Location>
equipmentTypeJS_ENUMtopology::JSEquipTypeunknown, breaker, disconnector, energyConsumer, energySource, fuse, generatingUnit, intersections, jumper, linearShuntCompensator, lineSegment, loadBreakSwitch, powerElectronicsConnection, powerTransformer, recloser, transformerTank, voltageRegulator, transformer, controllableLoad, last
siblingsvector<string>
regionsvector<string>
baseVoltagefloatNominal line-to-line circuit voltage

Top

Fuse - extends Equipment

FieldTypeLabelDescription

Top

Generating Unit - extends Equipment

FieldTypeLabelDescription
ratedSdouble
powerFactordouble

Top

Generic Switch - extends Equipment

FieldTypeLabelDescription
normalOpenbool
closedbooltrue

Top

Intersections - extends Equipment

FieldTypeLabelDescription
connectedCountint

Top

Jumper - extends Equipment

FieldTypeLabelDescription

Top

Linear Shunt Compensator - extends Equipment

FieldTypeLabelDescription
bPerSectiondouble
nomUdouble
varsdouble

Top

Line Segment - extends Equipment

FieldTypeLabelDescription

Top

Load Break Switch - extends Generic Switch

FieldTypeLabelDescription

Top

Power Electronics Connection - extends Equipment

FieldTypeLabelDescription
unitJS_ENUMtopology::DC Unit
maxIFaultdouble
pdouble
qdouble
ratedSdouble
ratedUdouble

Top

Power Transformer - extends Equipment

FieldTypeLabelDescription
highVfloat
lowVfloat

Top

Recloser - extends Generic Switch

FieldTypeLabelDescription
breakingCapacityint

Top

Region

FieldTypeLabelDescription
namestring
mridstring

Top

Transformer Tank - extends Equipment

FieldTypeLabelDescription
ptIdstring

Top

Voltage Regulator - extends Equipment

FieldTypeLabelDescription
lowStepint
highStepint
voltsint
normalStepint
svifloat